X
Search Filters
Format Format
Subjects Subjects
Subjects Subjects
X
Sort by Item Count (A-Z)
Filter by Count
detectors (8) 8
nuclear science & technology (8) 8
gamma rays (7) 7
activation-analysis (5) 5
spectroscopy (5) 5
boron (4) 4
cadmium (4) 4
chemistry, inorganic & nuclear (4) 4
chlorine (4) 4
instruments & instrumentation (4) 4
physics, particles & fields (4) 4
accelerators (3) 3
analysis (3) 3
concrete (3) 3
explosive and narcotic proxy material samples (3) 3
pgnaa (3) 3
portability (3) 3
portable neutron generator (3) 3
radiology, nuclear medicine & medical imaging (3) 3
water (3) 3
bgo (2) 2
bgo detector (2) 2
boron and cadmium (2) 2
bulk sampling (2) 2
cadmium and boron concentration (2) 2
concentration measurements (2) 2
generators (2) 2
hydrogen (2) 2
interference of detector associated and sample associated gamma rays (2) 2
labr:ce detector (2) 2
lacl3-ce (2) 2
lacl:ce detector (2) 2
measurement in water samples (2) 2
monte carlo simulations (2) 2
nai (2) 2
neutron (2) 2
nitrogen detection in bulk samples (2) 2
performance (2) 2
portable neutron generator based pgnaa setup (2) 2
prompt gamma ray studies (2) 2
scintillation detector (2) 2
system (2) 2
thermal neutron capture based pgnaa setup using 350 kev accelerator (2) 2
urea (2) 2
water samples (2) 2
14 mev neutron inelastic scattering induced prompt gamma rays (1) 1
14 mev neutron inelastic scattering: neutron moderation in bulk hydrocarbon samples: enhanced chlorine background in laci3:ce detector spectrum (1) 1
14mev neutron inelastic scattering induced prompt gamma rays (1) 1
activation (1) 1
activation analysis (1) 1
article subject (1) 1
astrophysics (1) 1
beams (1) 1
biochemical research methods (1) 1
bismuth (1) 1
bulk hydrocarbon samples (1) 1
bulk hydrocarbon samples, 14 mev neutron inelastic scattering: neutron moderation in bulk hydrocarbon samples: enhanced chlorine background in lacl (1) 1
bulk hydrocarbon samples, 14 mev neutron inelastic scattering: neutron moderation in bulk hydrocarbon samples: enhanced chlorine background in lacl3:ce detector spectrum (1) 1
calibration (1) 1
carbon - analysis (1) 1
ce detector spectrum (1) 1
cement concrete (1) 1
cements (1) 1
chemical engineering (1) 1
chemistry (1) 1
chemistry, analytical (1) 1
chloride analysis in superpozz concrete (1) 1
chloride concentration measurement using backward emitted prompt gamma rays (1) 1
chlorides (1) 1
chlorine concentration (1) 1
cl detector (1) 1
cl detector limitation for oxygen detection in hydrocarbon sample (1) 1
comparison of experimental and calculation results (1) 1
computer simulation (1) 1
concentration (1) 1
concrete corrosion studies (1) 1
concrete structures (1) 1
concretes (1) 1
contamination (1) 1
corrosion and anti-corrosives (1) 1
counting (1) 1
detector (1) 1
diagnostic radiology (1) 1
effectiveness (1) 1
electrical engineering (1) 1
engineering (1) 1
engineering, general (1) 1
equipment design (1) 1
equipment failure analysis (1) 1
fast neutrons (1) 1
fly ash concrete samples (1) 1
formic acid (1) 1
gamma-rays (1) 1
hg contaminated bulk water samples (1) 1
high energy astrophysical phenomena (1) 1
hydrogen - analysis (1) 1
index medicus (1) 1
inelastic scattering (1) 1
inorganic chemistry (1) 1
interference of 6.11 mev oxygen and 6.13 mev chlorine gamma rays (1) 1
more...
Language Language
Publication Date Publication Date
Click on a bar to filter by decade
Slide to change publication date range


Nuclear Instruments and Methods in Physics Research, A, ISSN 0168-9002, 08/2013, Volume 719, p. 39
Despite their poor oxygen detection capabilities, these detectors have nonetheless excellent detection capabilities for hydrogen and carbon in benzene, butyl... 
Gamma rays | Hydrogen | Analysis | Formic acid | Detectors | Organic acids
Journal Article
Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 11/2013, Volume 729, pp. 8 - 13
Nitrogen concentration was measured in explosive and narcotics proxy material, e.g. anthranilic acid, caffeine, melamine, and urea samples, bulk samples... 
BGO detector | Monte Carlo simulations | Thermal neutron capture based PGNAA setup using 350 keV accelerator | Nitrogen detection in bulk samples | Explosive and narcotic proxy material samples | Gamma rays | Urea | Detectors
Journal Article
Applied Radiation and Isotopes, ISSN 0969-8043, 08/2013, Volume 78, p. 145
Hydrogen, carbon and oxygen concentrations were measured in caffeine, urea, ammonium acetate and melamine bulk samples via 14MeV neutron inelastic scattering... 
Gamma rays | Urea | Hydrogen | Analysis | Detectors
Journal Article
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine, 05/2012, Volume 70, Issue 5, pp. 882 - 887
The yield of 478 and 558 keV gamma-rays have been measured from water samples containing 0.031-0.500 wt. % boron and 0.0625-0.500 wt. % cadmium, respectively,... 
Journal Article
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, 2013, Volume 729, pp. 8 - 13
Journal Article
Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 08/2013, Volume 719, pp. 39 - 43
Journal Article
Applied Radiation and Isotopes, ISSN 0969-8043, 05/2012, Volume 70, Issue 5, pp. 882 - 887
Journal Article
Applied Radiation and Isotopes, ISSN 0969-8043, 05/2012, Volume 70, Issue 5, pp. 882 - 887
The yield of 478 and 558keV gamma-rays have been measured from water samples containing 0.031-0.500wt. % boron and 0.0625-0.500wt. % cadmium, respectively,... 
LaCl:Ce detector | Concentration measurements | Boron and cadmium | Interference of detector associated and sample associated gamma rays | Portable neutron generator based PGNAA setup | Water samples
Journal Article
Applied Radiation and Isotopes, ISSN 0969-8043, 08/2012, Volume 70, Issue 8, pp. 1671 - 1674
Journal Article
Journal of Spectroscopy, ISSN 2314-4920, 2013, Volume 1, Issue 1, pp. 1 - 7
Nitrogen concentration was measured via 2.52 MeV nitrogen gamma ray from melamine, caffeine, urea, and disperse orange bulk samples using a newly designed D-D... 
SYSTEM | TESTS | SPECTROSCOPY | BIOCHEMICAL RESEARCH METHODS
Journal Article
11/2014
The system for measuring chlorine concentration in fly ash cement concrete utilizes a portable neutron generator and a gamma-ray detector for performing prompt... 
TESTING | INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIRCHEMICAL OR PHYSICAL PROPERTIES | MEASURING | PHYSICS
Patent
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, ISSN 0168-9002, 02/2012, Volume 665, pp. 74 - 79
The response of a cylindrical 3 in. x 3 in. (height x diameter) LaBr3:Ce detector was measured for low energy prompt gamma-rays from boron and cadmium... 
Measurement in water samples | CALIBRATION | Cadmium and boron concentration | CHLORINE | CONCRETE | INSTRUMENTS & INSTRUMENTATION | Prompt gamma ray studies | SPECTROSCOPY | NUCLEAR SCIENCE & TECHNOLOGY | LaBr:Ce detector | RAY ACTIVATION-ANALYSIS | PGNAA | WATER | PHYSICS, PARTICLES & FIELDS
Journal Article
Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 2011, Volume 665, pp. 74 - 79
The response of a cylindrical 3 in.×3 in. (height×diameter) LaBr :Ce detector was measured for low energy prompt gamma-rays from boron and cadmium contaminated... 
Measurement in water samples | LaBr:Ce detector | Prompt gamma ray studies | Cadmium and boron concentration
Journal Article
Nuclear Instruments & Methods in Physics Research. Section A. Accelerators, Spectrometers, Detectors, and Associated Equipment, ISSN 0168-9002, 02/2011, Volume 665, pp. 74 - 79
The response of a cylindrical 3 in.x3 in. (heightxdiameter) LaBr sub(3:Ce detector was measured for low energy prompt gamma-rays from boron and cadmium... 
Low energy | Cadmium | Boron | Monte Carlo methods | Accelerators | Mathematical analysis | Detectors | Contamination
Journal Article
Arabian Journal for Science and Engineering, ISSN 1319-8025, 1/2014, Volume 39, Issue 1, pp. 531 - 539
Performance of a D–D reaction-based portable pulsed neutron generator model MP320 was evaluated for prompt gamma applications. The operating beam energy and... 
Portable neutron generator | Engineering | Neutron flux efficacy | Engineering, general | Prompt gamma-ray | Science, general | Chlorine concentration | ACTIVATION-ANALYSIS | MULTIDISCIPLINARY SCIENCES | CHLORINE | CONCRETE | PGNAA | WATER | Beams (radiation) | Saline water | Effectiveness | Chlorine | Generators | Portability | Iron | Activation analysis
Journal Article
01/2014, ISBN 9781321229622
The structure of many first principle engineering models is in the form of non-linear differential algebraic equations (DAE). Standard system theory, however,... 
Electrical engineering | Chemical engineering
Dissertation
No results were found for your search.

Cannot display more than 1000 results, please narrow the terms of your search.