X
Search Filters
Format Format
Format Format
X
Sort by Item Count (A-Z)
Filter by Count
Journal Article (447) 447
Publication (63) 63
Conference Proceeding (9) 9
Book / eBook (8) 8
Book Chapter (4) 4
Book Review (2) 2
Dissertation (1) 1
Government Document (1) 1
Newspaper Article (1) 1
Paper (1) 1
more...
Subjects Subjects
Subjects Subjects
X
Sort by Item Count (A-Z)
Filter by Count
chemistry, analytical (211) 211
spectroscopy (185) 185
ionic mobility (174) 174
mass spectrometry (153) 153
ions (131) 131
drift (121) 121
index medicus (112) 112
ion mobility spectrometry (102) 102
ion mobility (98) 98
separation (98) 98
chemistry (95) 95
drift tubes (95) 95
analytical chemistry (92) 92
biochemical research methods (88) 88
mass-spectrometry (88) 88
spectrometry (84) 84
analysis (83) 83
proteomics (83) 83
chemistry, physical (77) 77
scientific imaging (74) 74
drift-tube (73) 73
ionization (72) 72
mobility (72) 72
resolution (72) 72
ionenbeweglichkeit (63) 63
organic chemistry (60) 60
gas-phase (57) 57
ion-mobility (50) 50
bioinformatics (49) 49
biotechnology (49) 49
physics, atomic, molecular & chemical (49) 49
laufzeitröhre (48) 48
article (44) 44
collision cross-sections (43) 43
electrospray-ionization (43) 43
mass spectrometry - methods (42) 42
drift-tubes (41) 41
peptides (41) 41
proteins (41) 41
isomers (40) 40
drift tube (38) 38
spectrum analysis (38) 38
usage (38) 38
mobilität (34) 34
chromatography (33) 33
mass spectroscopy (33) 33
cross sections (32) 32
ions - chemistry (30) 30
massenspektrometrie (29) 29
spectrometers (29) 29
electric fields (28) 28
plasma chromatography (28) 28
gas (26) 26
calibration (25) 25
physical chemistry (25) 25
research (25) 25
dissociation (24) 24
nitrogen (24) 24
performance (24) 24
humans (23) 23
animals (22) 22
liquid-chromatography (22) 22
explosives (21) 21
helium (21) 21
liquid chromatography (21) 21
spektrometrie (21) 21
auflösungsvermögen (20) 20
ecotoxicology (20) 20
equipment design (20) 20
identification (20) 20
molecular medicine (20) 20
algorithms (19) 19
atmospheric-pressure (19) 19
drift gas (19) 19
instruments & instrumentation (19) 19
mass spectrometry - instrumentation (19) 19
mathematical analysis (19) 19
pressure (19) 19
safety in chemistry, dangerous goods (19) 19
separating (19) 19
structural-characterization (19) 19
biomolecules (18) 18
cytochrome-c (18) 18
instrumentation related to nuclear science and technology (18) 18
isomerism (18) 18
peptide (18) 18
physics (18) 18
resolution:resolving (18) 18
temperature (18) 18
air (17) 17
flight mass-spectrometry (17) 17
fragmentation (17) 17
sensitivity (17) 17
spectra (17) 17
collisions (16) 16
metabolites (16) 16
methods (16) 16
physics, applied (16) 16
resolving power (16) 16
stossquerschnitt (16) 16
more...
Library Location Library Location
Language Language
Publication Date Publication Date
Click on a bar to filter by decade
Slide to change publication date range


Chemical Science, ISSN 2041-6520, 01/2017, Volume 8, Issue 11, pp. 7724 - 7736
The confident identification of metabolites and xenobiotics in biological and environmental studies is an analytical challenge due to their immense dynamic... 
Urine | Spectroscopy | Downloading | Ionic mobility | Calibration | Metabolism | Data bases | Collision dynamics | Flavonoids | Databases | Metabolites | Antibiotics | Polycyclic aromatic hydrocarbons | Pentose | Glycolysis | Environmental studies | Scientific imaging | Drift | Terpenes | Mass spectrometry | Cross sections
Journal Article
Physical Chemistry Chemical Physics, ISSN 1463-9076, 04/2014, Volume 16, Issue 15, pp. 6968 - 6979
Improved methods are needed to study sorption of vapor molecules by particles in the gas phase (heterogeneous uptake), which is an important process in both... 
AEROSOL-PARTICLES | CONDENSATION PARTICLE COUNTER | TRANSITION REGIME | AQUEOUS-SOLUTIONS | SULFATE PARTICLES | SIZE | GROWTH | PHYSICS, ATOMIC, MOLECULAR & CHEMICAL | CHEMISTRY, PHYSICAL | NUCLEATION | DELIQUESCENCE
Journal Article
Analytical Chemistry, ISSN 0003-2700, 10/2018, Volume 90, Issue 20, pp. 12042 - 12050
Collision cross section (CCS, Ω) values determined by ion mobility mass spectrometry (IM-MS) provide the study of ion shape in the gas phase and use of these... 
CALIBRATION | CHEMISTRY, ANALYTICAL | SMALL MOLECULES | DATABASE | COLLISION CROSS-SECTION | GAS-PHASE | PROTEIN COMPLEXES | STRUCTURAL-CHARACTERIZATION | SEPARATION | AMINOBENZOIC ACID | PEPTIDE
Journal Article
Analytical Chemistry, ISSN 0003-2700, 10/2018, Volume 90, Issue 20, p. 12042
Collision cross section (CCS, Ω) values determined by ion mobility mass spectrometry (IM-MS) provide the study of ion shape in the gas phase and use of these... 
Solvents | Spectroscopy | Disintegration | Vapor phases | Ionic mobility | Mobility | Traveling waves | Mass spectroscopy | Flow rates | Data bases | Studies | Molecules | Databases | Sodium | Gas flow | Ionization | Influence | Protonation | Flow velocity | Drift | Drift tubes | Mass spectrometry | Adducts
Journal Article
ANALYTICAL CHEMISTRY, ISSN 0003-2700, 11/2019, Volume 91, Issue 21, pp. 13555 - 13561
Ion mobility was integrated with liquid chromatography/high resolution mass spectrometry (LC/IM-HRMS) to quantify 25-hydroxyvitamin D (250HD) in human serum.... 
CHEMISTRY, ANALYTICAL | C-3 EPIMERIZATION | D DEFICIENCY | INSUFFICIENCY | VITAMIN-D METABOLITES | EPIMERS | SKYLINE | Spectroscopy | Bias | Ionic mobility | Mobility | Ions | Mass spectroscopy | Liquid chromatography | Quantitation | Standards | Chromatography | Albumins | Ionization | Quality control | Scientific imaging | Drift | Drift tubes | Mass spectrometry | Conformation | 25-Hydroxyvitamin D
Journal Article
Analytical Chemistry, ISSN 0003-2700, 09/2017, Volume 89, Issue 17, p. 9048
Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of... 
Analytical chemistry | Spectroscopy | Integration | Laboratories | Standardization | Ionic mobility | Mobility | Ions | Mass spectroscopy | Molecules | Reproducibility | Stepped | Drift | Reference systems | Mass spectrometry | Cross sections | Interlaboratory
Journal Article
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, ISSN 1044-0305, 06/2019, Volume 30, Issue 6, pp. 1059 - 1068
Journal Article
Journal Article
Journal of The American Society for Mass Spectrometry, ISSN 1044-0305, 2/2019, Volume 30, Issue 2, pp. 256 - 267
Journal Article
Analytical Chemistry, ISSN 0003-2700, 11/2017, Volume 89, Issue 21, pp. 11301 - 11309
Atmospheric pressure drift tube ion mobility spectrometry (AP-DTIMS) was coupled with Fourier transform Orbitrap mass spectrometry. The performance... 
RESOLVING POWER | MIXTURES | CHEMISTRY, ANALYTICAL | PROTEIN | SEPARATION | PEPTIDE
Journal Article
Angewandte Chemie, ISSN 1433-7851, 07/2014, Volume 53, Issue 30, pp. 7765 - 7769
  Collision cross-sections (CCS) of immunoglobulins G1 and G4 have been determined using linear drift-tube ion-mobility mass spectrometry. Intact antibodies... 
Mass spectrometry | Proteins | Immunoglobulins | Dynamics | Antibodies | Fragments | Drift | Cross sections | Collision dynamics
Journal Article
Analytical Chemistry, ISSN 0003-2700, 11/2017, Volume 89, Issue 21, p. 11301
Atmospheric pressure drift tube ion mobility spectrometry (AP-DTIMS) was coupled with Fourier transform Orbitrap mass spectrometry. The performance... 
Analytical chemistry | Spectroscopy | Fourier transforms | Atmospheric pressure | Ionic mobility | Mobility | Mass spectroscopy | Parameter sensitivity | Isomers | Drift | Energy of dissociation | Mass spectrometry | Gating | Sugar | Resolution
Journal Article
ANALYST, ISSN 0003-2654, 9/2015, Volume 14, Issue 2, pp. 6955 - 6963
Multidimensional high throughput separations are ideal for analyzing distinct ion characteristics simultaneously in one analysis. We report on the first... 
CHEMISTRY, ANALYTICAL | CONFORMERS | HELIUM | TRANSPORT GAS | Platforms | Separation | Ion mobility | Asymmetry | Ionic mobility | Drift tubes | Mass spectrometry | Three dimensional
Journal Article
Analytical Chemistry, ISSN 0003-2700, 01/2019, Volume 91, Issue 1, pp. 919 - 927
Ion motion in trapped ion mobility spectrometers (TIMS) and inverted drift tubes (IDT) has been investigated. The two-dimensional (2D) axisymmetric analytical... 
CHEMISTRY, ANALYTICAL | FUNDAMENTALS | MASS | Confinement | Ionic mobility | Mobility | Axial diffusion | Ions | Velocity distribution | Radio frequency | Spectrometry | Dynamic tests | Spectrometers | Ion motion | Scientific imaging | Drift | Drift tubes | Diffusion | Two dimensional analysis | Electric fields
Journal Article
Journal of The American Society for Mass Spectrometry, ISSN 1044-0305, 10/2019, Volume 30, Issue 10, pp. 2152 - 2162
Using contemporary theory for ion mobility spectrometry (IMS), gas-phase ion mobilities within a trapped ion mobility-mass spectrometer (TIMS) are not easily... 
Biotechnology | Drift-tube ion mobility spectrometry | Chemistry | Analytical Chemistry | Trapped ion mobility spectrometry | Proteomics | Ion mobility calibration | Bioinformatics | Mass spectrometry | Organic Chemistry | Ammonium compounds | Physical instruments | Ammonium paratungstate | Circuit printing | Printed circuits
Journal Article