X
Search Filters
Format Format
Subjects Subjects
Subjects Subjects
X
Sort by Item Count (A-Z)
Filter by Count
central corneal thickness (6) 6
ophthalmology (6) 6
dual scheimpflug analyzer (5) 5
eye (5) 5
index medicus (5) 5
surgery (5) 5
ultrasound pachymetry (5) 5
cornea (4) 4
dual rotating scheimpflug camera (4) 4
galilei (4) 4
optical coherence tomography (4) 4
orbscan-ii (4) 4
analysis (3) 3
anterior segment optical coherence tomography (3) 3
corneal thickness (3) 3
eyes (3) 3
humans (3) 3
in-situ keratomileusis (3) 3
methods (3) 3
original (3) 3
repeatability (3) 3
reproducibility (3) 3
system (3) 3
tomography (3) 3
usage (3) 3
astigmatism (2) 2
cataract (2) 2
cornea - diagnostic imaging (2) 2
cornea - pathology (2) 2
eye diseases (2) 2
female (2) 2
galilei dual scheimpflug analyzer (2) 2
genetic structures (2) 2
glaucoma (2) 2
keratoconus (2) 2
male (2) 2
medical imaging (2) 2
medicine (2) 2
middle aged (2) 2
original article (2) 2
particle image velocimetry (2) 2
pentacam (2) 2
photorefractive keratectomy (2) 2
physics, fluids & plasmas (2) 2
reproducibility of results (2) 2
scheimpflug (2) 2
sense organs (2) 2
topography (2) 2
ultrasonography (2) 2
ultrasound (2) 2
30 eyes of 15 patients with pacg (1) 1
abwärtsströmung (1) 1
accuracy (1) 1
acd (1) 1
adult (1) 1
age-related macular degeneration (1) 1
aged (1) 1
aged, 80 and over (1) 1
agreement (1) 1
and 66 eyes of 33 healthy subjects were evaluated. patients who underwent previous ophthalmic surgery and contact lens wearers were excluded. after full ophthalmological examination (1) 1
and healthy eyes. materials and methods: one hundred forty-three eyes of 86 patients were included in this study. forty-seven eyes of 38 patients with pexg (1) 1
and mean anterior chamber angle were measured by dual scheimpflug corneal topography and compared between the three groups. statistical analyses were done using statistical package for social sciences for windows 18.0 program. results: no statistical difference was found in mean age or gender among the study groups. there were also no statistical differences in cct (1) 1
angle-closure glaucoma (1) 1
anterior chamber (1) 1
anterior chamber depth (1) 1
anterior chamber volume (1) 1
anterior corneal astigmatism (1) 1
article (1) 1
associations (1) 1
asymmetry (1) 1
axial length (1) 1
branches (1) 1
calculation formulas (1) 1
cataract surgery (1) 1
cataract-surgery (1) 1
ccd-kamera (1) 1
children (1) 1
computational fluid dynamics (1) 1
contact lenses (1) 1
cornea - anatomy & histology (1) 1
cornea - surgery (1) 1
corneal (1) 1
corneal pachymetry - instrumentation (1) 1
corneal power (1) 1
corneal surgery, laser (1) 1
corneal topography - instrumentation (1) 1
critical height (1) 1
curved surface (1) 1
data covariances (1) 1
demographics (1) 1
demography (1) 1
devices (1) 1
diagnostic techniques, ophthalmological - instrumentation (1) 1
diagnostic techniques, ophthalmological - standards (1) 1
disease (1) 1
drag reduction (1) 1
dual discharge (1) 1
dual scheimpflug analyger (1) 1
dual scheimpflug topography system (1) 1
dual-plane piv measurement (1) 1
more...
Language Language
Publication Date Publication Date
Click on a bar to filter by decade
Slide to change publication date range


Journal of the Korean Ophthalmological Society, ISSN 0378-6471, 10/2015, Volume 56, Issue 10, pp. 1520 - 1526
To compare central corneal thickness (CCT) as measured using noncontact specular microscopy (NCSM), dual rotating Scheimpflug camera (Galilei®), and... 
Noncontact microscopy | Ultrasound pachymet | Central corneal thickness | Dual rotating scheimpflug camera
Journal Article
Journal of the Korean Ophthalmological Society, ISSN 0378-6471, 10/2012, Volume 53, Issue 10, pp. 1412 - 1418
To compare central corneal thickness (CCT) as measured by dual rotating Scheimpflug camera (Galilei), anterior segment optical coherence tomography (AS-OCT),... 
Ultrasound pachymetry | Central corneal thickness | anterior segment optical coherence tomography | Dual rotating scheimpflug camera | GALILEI
Journal Article
대한안과학회지, ISSN 0378-6471, 2012, Volume 53, Issue 10, pp. 1412 - 1418
Purpose: To compare central corneal thickness (CCT) as measured by dual rotating Scheimpflug camera (Galilei), anterior segment optical coherence tomography... 
Ultrasound pachymetry | Galilei | Central corneal thickness | Anterior segment optical coherence tomography | Dual rotating scheimpflug camera
Journal Article
International Journal of Safety, ISSN 1598-7302, 2003, Volume 2, Issue 1, p. 1412
목적: 이중샤임플러그 전안부사진기(Galilei), 전안부 빛간섭단층촬영계 및 초음파 각막두께측정계를 이용하여 중심각막두께의 측정치를 비교하고자 한다.대상과 방법: 정상인 20명 40안을 대상으로 이중샤임플러그, 전안부 빛간섭단층촬영계, 그리고 초음파 각막두께측정계로 측정된... 
Ultrasound pachymetry | Central corneal thickness | Anterior segment optical coherence tomography | Galilei | Dual rotating scheimpflug camera
Journal Article
Journal of the Chinese Medical Association, ISSN 1726-4901, 2018, Volume 82, Issue 1, pp. 72 - 77
Background: Post-LASIK corneal conditions cannot be accurately measured by traditional optometric approaches. Therefore, we aimed to analyze the agreement of... 
Laser-assisted in situ keratomileusis (LASIK) | Pentacam | Corneal power | Corneal thickness | GALILEI | IN-SITU KERATOMILEUSIS | EYES | ORBSCAN-II | MEDICINE, GENERAL & INTERNAL | REPEATABILITY | ULTRASOUND | REFRACTIVE SURGERY | CATARACT | DUAL SCHEIMPFLUG ANALYZER
Journal Article
Journal of the Korean Ophthalmological Society, ISSN 0378-6471, 03/2016, Volume 57, Issue 3, pp. 369 - 379
To investigate the accuracy of intraocular lens power calculations using simulated keratometry (simK) of dual Scheimpflug analyzer and 5 types of formulas in... 
Cataract surgery | Intraocular lens power calculation | Dual Scheimpflug analyger
Journal Article
Scientific Reports, ISSN 2045-2322, 12/2018, Volume 8, Issue 1, pp. 1304 - 8
To assess the repeatability and reproducibility of AL-Scan in agreement with those by the IOLMaster in healthy children, two skilled operators measured ocular... 
CORNEAL THICKNESS | ULTRASOUND PACHYMETRY | AXIAL LENGTH | REPEATABILITY | OPTICAL COHERENCE TOMOGRAPHY | MULTIDISCIPLINARY SCIENCES | INTERFEROMETRY | DEVICES | AGREEMENT | REPRODUCIBILITY | DUAL SCHEIMPFLUG ANALYZER | Cornea | Anterior chamber | Children | Index Medicus
Journal Article
Journal of Ophthalmic and Vision Research, ISSN 2008-2010, 01/2016, Volume 11, Issue 1, pp. 8 - 16
To determine the predictive ability of different data measured by the Galilei dual Scheimpflug analyzer in differentiating subclinical keratoconus and... 
Galilei Dual Scheimpflug Analyzer | Subclinical Keratoconus | Keratoconus | Treatment outcome | Usage | Analysis | Photorefractive keratectomy | Studies | Medical imaging | Asymmetry | Contact lenses | Surgery | Topography | Methods | Astigmatism | Original | Galilei Dual Scheimpflug Analyzer; Keratoconus; Subclinical Keratoconus
Journal Article
国际眼科杂志:英文版, ISSN 2222-3959, 2016, Issue 9, pp. 1283 - 1288
AIM:To evaluate corneal parameters measured with a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring... 
keratoconus;intrastromal | corneal | ring | segments;dual | Scheimpflug
Journal Article
Journal of Cataract & Refractive Surgery, ISSN 0886-3350, 06/2018, Volume 44, Issue 6, pp. 701 - 708
To evaluate the results of intraocular lens (IOL) power calculation using different corneal power measurements provided by an optical biometer combined with a... 
SYSTEM | TOMOGRAPHY | SURGERY | EYES | IOLMASTER | OPHTHALMOLOGY | CALCULATION FORMULAS | PARTIAL COHERENCE INTERFEROMETRY | CATARACT-SURGERY | DUAL SCHEIMPFLUG ANALYZER | ACCURACY | PREDICTION | Medical colleges | Usage | Cataract | Ophthalmology | Analysis | Surgery
Journal Article
Turkish Journal of Ophthalmology, ISSN 2149-8695, 10/2018, Volume 48, Issue 5, pp. 227 - 231
To evaluate anterior segment parameters measured by dual Scheimpflug corneal topography in pseudoexfoliative glaucoma (PEXG), primary angle-closure glaucoma... 
Pseudoexfoliative glaucoma | Dual scheimpflug topography system | Primary angle-closure glaucoma | Glaucoma | Hypertension | Cornea | Optic nerve | Medical imaging | Statistical analysis | Tomography | Optics | primary angle-closure glaucoma | dual Scheimpflug topography system | Original | and healthy eyes. Materials and Methods: One hundred forty-three eyes of 86 patients were included in this study. Forty-seven eyes of 38 patients with PEXG | and mean anterior chamber angle were measured by dual Scheimpflug corneal topography and compared between the three groups. Statistical analyses were done using Statistical Package for Social Sciences for Windows 18.0 program. Results: No statistical difference was found in mean age or gender among the study groups (p>0.05). There were also no statistical differences in CCT | ACD | white-to-white horizontal corneal diameter (WTW) | mean central corneal thickness (CCT) | p=0.064 | Objectives: To evaluate anterior segment parameters measured by dual Scheimpflug corneal topography in pseudoexfoliative glaucoma (PEXG) | anterior chamber volume (ACV) | respectively). ACV | or PD among the groups (p=0.568 | p=0.321 | 30 eyes of 15 patients with PACG | anterior chamber depth (ACD) | pupillary diameter (PD) | primary angle-closure glaucoma (PACG) | and 66 eyes of 33 healthy subjects were evaluated. Patients who underwent previous ophthalmic surgery and contact lens wearers were excluded. After full ophthalmological examination | WTW
Journal Article
International Ophthalmology, ISSN 0165-5701, 04/2018, Volume 38, Issue 2, pp. 481 - 491
Purpose To evaluate the magnitude and axis orientation of the anterior, posterior, and total corneal astigmatism in normal healthy eyes of an Iranian... 
Dual Scheimpflug analyzer | Healthy eye | Total corneal astigmatism | Posterior corneal astigmatism | Anterior corneal astigmatism | Astigmatism | OPHTHALMOLOGY | Eye | Cornea | Demographics | Demography | Parameters | Surgery | Population studies | Ophthalmology | Females | Males | Intraocular lenses | Index Medicus
Journal Article
European Journal of Mechanics / B Fluids, ISSN 0997-7546, 03/2019, Volume 74, pp. 99 - 110
Vortical structure in wall turbulence over a sinusoidal riblet surface is investigated by means of a dual-plane stereoscopic particle image velocimetry... 
Dual-plane PIV measurement | Turbulent flow | Drag reduction | Sinusoidal riblet | PARTICLE IMAGE VELOCIMETRY | MECHANICS | GRADIENT TENSOR-FIELDS | SKIN-FRICTION | PHYSICS, FLUIDS & PLASMAS | FRICTION DRAG REDUCTION | SHEAR-FLOW | REYNOLDS-NUMBER DEPENDENCE
Journal Article
Experimental Thermal and Fluid Science, ISSN 0894-1777, 2011, Volume 35, Issue 1, pp. 82 - 95
Journal Article
No results were found for your search.

Cannot display more than 1000 results, please narrow the terms of your search.