X
Search Filters
Format Format
Subjects Subjects
Subjects Subjects
X
Sort by Item Count (A-Z)
Filter by Count
chemistry, analytical (45) 45
index medicus (36) 36
biochemical research methods (32) 32
kinetex-c-18 (29) 29
shell particles (23) 23
performance (20) 20
chromatography (16) 16
core-shell particles (16) 16
kinetex (16) 16
performance liquid-chromatography (16) 16
separation (16) 16
liquid chromatography (15) 15
analysis (13) 13
chromatography, high pressure liquid - methods (13) 13
mass-transfer kinetics (13) 13
column packing technology (12) 12
core-shell (12) 12
column efficiency (11) 11
hplc (11) 11
hetp (10) 10
diffusion (9) 9
eddy diffusion (9) 9
efficiency (9) 9
gradient elution (9) 9
kinetex-c (9) 9
shells (9) 9
particles (8) 8
solid-phase extraction (8) 8
kinetex-c 18 (7) 7
mass spectrometry (7) 7
optimization (7) 7
pharmacology & pharmacy (7) 7
superficially porous particles (7) 7
column-to-column repeatability (6) 6
insulin (6) 6
kinetex-c-18 particles (6) 6
kinetic plots (6) 6
longitudinal diffusion (6) 6
pressure (6) 6
silica particles (6) 6
band-broadening contributions (5) 5
column packings (5) 5
core–shell (5) 5
equation (5) 5
food (5) 5
halo-c-18 (5) 5
heterogeneity (5) 5
high performance liquid chromatography (5) 5
mass transfer (5) 5
particle size (5) 5
peak capacity (5) 5
solid-liquid mass transfer resistance (5) 5
speed (5) 5
stationary phases (5) 5
temperature (5) 5
transfer kinetics (5) 5
validation (5) 5
acetonitrile (4) 4
animals (4) 4
bradykinin (4) 4
chemistry (4) 4
chromatography, high pressure liquid - instrumentation (4) 4
columns (4) 4
corticosteroids (4) 4
elution (4) 4
equivalence (4) 4
external mass-transfer (4) 4
extraction (4) 4
halo (4) 4
halo-c (4) 4
halo-c 18 (4) 4
limit of detection (4) 4
liquid-chromatography (4) 4
lyzozyme (4) 4
mathematical analysis (4) 4
mathematical models (4) 4
methods (4) 4
milk (4) 4
naphtho[2,3-a]pyrene (4) 4
peak-capacity (4) 4
phase liquid-chromatography (4) 4
porosity (4) 4
proteins (4) 4
reproducibility of results (4) 4
technology (4) 4
van deemter plot (4) 4
beds (3) 3
core–shell particles (3) 3
cortecs (3) 3
dispersion (3) 3
eddy dispersion term (3) 3
food science & technology (3) 3
heat friction (3) 3
inorganic, organic, physical and analytical chemistry (3) 3
kinetex column (3) 3
kinetex xb hplc column (3) 3
kinetex-c18 (3) 3
kinetic plot (3) 3
kinetics (3) 3
lc-ms/ms (3) 3
more...
Language Language
Publication Date Publication Date
Click on a bar to filter by decade
Slide to change publication date range


Journal of Chromatography A, ISSN 0021-9673, 2010, Volume 1217, Issue 18, pp. 3000 - 3012
A series of experiments and measurements demonstrate the importance of minimizing the extra-column band broadening contribution of the instrument used. The... 
Shell particles | Instrumentation | Agilent 1290 Infinity HPLC | Variance | Resolutions | Column packing technology | Column efficiency | Agilent 1200 | Agilent 1100 | Extra-column effects | Acquity | Kinetex-C 18 | Resolution | Kinetex-C | CHEMISTRY, ANALYTICAL | PARTICLES | DISPERSION | VOLUME | BIOCHEMICAL RESEARCH METHODS | Kinetex-C-18 | PRESSURE | TEMPERATURE | GAS
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 2010, Volume 1217, Issue 31, pp. 5069 - 5083
Surprisingly, the mass transfer kinetic properties of columns packed with superficially porous particles are markedly different from those of columns packed... 
Column packing technology | Van Deemter plot | Narrow-bore columns | Shell particles | Naphtho[2,3-a]pyrene | HETP | Heat friction | Kinetex-C 18 | Kinetex-C
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 2010, Volume 1217, Issue 52, pp. 8167 - 8180
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 2010, Volume 1217, Issue 10, pp. 1589 - 1603
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 03/2013, Volume 1280, pp. 35 - 50
► Columns packed with Kinetex 4.6 μm particles or 5 μm Luna have the same permeability. ► The 4.6 mm I.D. columns are more efficient than the 2.1 mm I.D. ones.... 
Column-to-column repeatability | Eddy diffusion | Longitudinal diffusion | Solid–liquid mass transfer resistance | Kinetex-C18 | Core–shell particles | Solid-liquid mass transfer resistance | Kinetex-C | Core-shell particles
Journal Article
Chemical Engineering Science, ISSN 0009-2509, 2010, Volume 65, Issue 23, pp. 6327 - 6340
Mass transfer kinetics in a particular column packed with Kinetex-C particles was measured using a series of non-invasive methods. According to the... 
Column packing technology | Halo-C 18 | HETP | Small molecules | Kinetex-C 18 | Shell particles | Kinetex-C | Halo-C
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 2010, Volume 1217, Issue 10, pp. 1604 - 1615
Journal Article
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, ISSN 0731-7085, 02/2011, Volume 54, Issue 3, pp. 482 - 490
At present sub-2 mu m packed columns are very popular to accomplish rapid and efficient separations. Applying particles with shortened diffusion path to... 
CHEMISTRY, ANALYTICAL | PARTICLES | KINETEX-C-18 | Sub-2 mu m particles | MASS-TRANSFER KINETICS | Core-shell | CAPILLARY COLUMNS | Kinetex | PERFORMANCE LIQUID-CHROMATOGRAPHY | SILICA COLUMNS | SPEED | Column efficiency | PRESSURE | PHARMACEUTICAL DEVELOPMENT | Kinetic plots | PACKING | PHARMACOLOGY & PHARMACY
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 2010, Volume 1217, Issue 23, pp. 3642 - 3653
Today sub-2 μm packed columns are very popular to conduct fast chromatographic separations. The mass-transfer resistance depends on the particle size but some... 
Column efficiency | Core–shell | Sub-2 μm particles | Kinetic plots | Kinetex | Core-shell | Sub-2μm particles
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 03/2010, Volume 1217, Issue 10, pp. 1589 - 1603
The performance of the new Kinetex-C column was investigated. Packed with a new brand of porous shell particles, this column has an outstanding efficiency.... 
Column packing technology | Van Deemter plot | Anthracene | Halo-C | Bradykinin | Shell particles | Acetonitrile | Naphtho[2,3-a]pyrene | HETP | Kinetex-C | Lyzozyme | Insulin
Journal Article
JOURNAL OF SEPARATION SCIENCE, ISSN 1615-9306, 02/2014, Volume 37, Issue 3, pp. 189 - 197
The aim of this study was to evaluate the possibilities/limitations of recent RP-LC columns packed with 1.6 mu m superficially porous particles (Waters... 
OVERLOAD | CHEMISTRY, ANALYTICAL | PEAK-CAPACITY | GRADIENT ELUTION | STATIONARY PHASES | CORE-SHELL PARTICLES | KINETEX-C-18 PARTICLES | BASIC COMPOUNDS | Cortecs | Kinetex | PERFORMANCE LIQUID-CHROMATOGRAPHY | IONIZED SOLUTES | Superficially porous particles | Kinetic plots | Column efficiencies | HPLC | Drugs | Separation | Phases | Stability | Peptides | Permeability | Bearing strength
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 09/2013, Volume 1308, pp. 104 - 113
The goal of this study was to critically evaluate a new generation of columns packed with 1.3 μm core–shell particles. The practical possibilities and... 
Column efficiency | Core–shell | Fast liquid chromatography | 1.3 μm particles | Kinetic plot | Kinetex | 1.3μm particles | Core-shell
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 03/2010, Volume 1217, Issue 10, pp. 1604 - 1615
The performance of columns packed with the new 2.6μ m Kinetex-C shell particles was investigated in gradient elution chromatography and compared with those of... 
Protein digest | Gradient elution | β-Lactoglobulin | Shell particles | Kinetex-C | Lyzozyme | Insulin | Column packing technology | Halo-C | Bradykinin | Acetonitrile | BEH-C | Peak capacity
Journal Article
Journal of Chromatography A, ISSN 0021-9673, 08/2012, Volume 1252, pp. 31 - 44
The column-to-column repeatability of the mass transfer mechanism in columns packed with sub-3μm shell particles was investigated. The parameters of this... 
Eddy diffusion | Solid-liquid mass transfer resistance | Column-to-column repeatability | Kinetex-C | Longitudinal diffusion | Core-shell particles
Journal Article
JOURNAL OF CHROMATOGRAPHY A, ISSN 0021-9673, 06/2010, Volume 1217, Issue 23, pp. 3642 - 3653
Today sub-2 mu m packed columns are very popular to conduct fast chromatographic separations. The mass-transfer resistance depends on the particle size but... 
KINETIC PERFORMANCE | ULTRA-HIGH PRESSURE | CHEMISTRY, ANALYTICAL | SMALL PARTICLES | Sub-2 mu m particles | BIOCHEMICAL RESEARCH METHODS | Core-shell | CAPILLARY COLUMNS | Kinetex | PERFORMANCE LIQUID-CHROMATOGRAPHY | SILICA COLUMNS | SPEED | Column efficiency | PHARMACEUTICAL DEVELOPMENT | Kinetic plots | SEPARATION | PRACTICAL ASPECTS
Journal Article