Circulation, ISSN 0009-7322, 04/2011, Volume 123, Issue 13, pp. 1400 - 1409
Background-Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific...
overlapping stents | thrombosis | malapposition | stents | hemodynamics | CARDIAC & CARDIOVASCULAR SYSTEMS | METAANALYSIS | BARE-METAL STENTS | INTRAVASCULAR ULTRASOUND GUIDANCE | ANTICOAGULATION | TRIAL | ELUTING STENTS | IMPLANTATION | RESTENOSIS | PERIPHERAL VASCULAR DISEASE | HEMATOLOGY | CORONARY-ARTERY-DISEASE | Polymers - administration & dosage | Thrombosis - pathology | Animals | Time Factors | Cattle | Drug-Eluting Stents - standards | Swine | Thrombosis - etiology | Risk Factors | Prosthesis Design - standards | Thrombosis - prevention & control | Drug-Eluting Stents - adverse effects | Complications and side effects | Drug-eluting stents | Design and construction | Research | Thrombosis | Blood clot | Risk factors | stent | overlap
overlapping stents | thrombosis | malapposition | stents | hemodynamics | CARDIAC & CARDIOVASCULAR SYSTEMS | METAANALYSIS | BARE-METAL STENTS | INTRAVASCULAR ULTRASOUND GUIDANCE | ANTICOAGULATION | TRIAL | ELUTING STENTS | IMPLANTATION | RESTENOSIS | PERIPHERAL VASCULAR DISEASE | HEMATOLOGY | CORONARY-ARTERY-DISEASE | Polymers - administration & dosage | Thrombosis - pathology | Animals | Time Factors | Cattle | Drug-Eluting Stents - standards | Swine | Thrombosis - etiology | Risk Factors | Prosthesis Design - standards | Thrombosis - prevention & control | Drug-Eluting Stents - adverse effects | Complications and side effects | Drug-eluting stents | Design and construction | Research | Thrombosis | Blood clot | Risk factors | stent | overlap
Journal Article
International Journal of Cardiology, ISSN 0167-5273, 2014, Volume 177, Issue 3, pp. 800 - 808
Abstract Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential...
Cardiovascular | Strut thickness | DES | Bioabsorbable scaffolds | Re-endothelialization | PCI | Neointimal coverage | CARDIAC & CARDIOVASCULAR SYSTEMS | OPTICAL COHERENCE TOMOGRAPHY | PERCUTANEOUS CORONARY | LONG-TERM OUTCOMES | BARE-METAL | TISSUE COVERAGE | CORONARY-ARTERY LESIONS | INTRAVASCULAR ULTRASOUND | DURABLE POLYMER | DRUG-ELUTING STENTS | BIORESORBABLE VASCULAR SCAFFOLD | Absorbable Implants - adverse effects | Tissue Scaffolds - adverse effects | Absorbable Implants - standards | Metals - standards | Humans | Risk Factors | Prosthesis Design - standards | Metals - adverse effects | Drug-Eluting Stents - adverse effects | Animals | Drug-Eluting Stents - standards | Prosthesis Design - methods | Tissue Scaffolds - standards | Stents - adverse effects | Stents - standards | Transluminal angioplasty | Stent (Surgery) | Alloys
Cardiovascular | Strut thickness | DES | Bioabsorbable scaffolds | Re-endothelialization | PCI | Neointimal coverage | CARDIAC & CARDIOVASCULAR SYSTEMS | OPTICAL COHERENCE TOMOGRAPHY | PERCUTANEOUS CORONARY | LONG-TERM OUTCOMES | BARE-METAL | TISSUE COVERAGE | CORONARY-ARTERY LESIONS | INTRAVASCULAR ULTRASOUND | DURABLE POLYMER | DRUG-ELUTING STENTS | BIORESORBABLE VASCULAR SCAFFOLD | Absorbable Implants - adverse effects | Tissue Scaffolds - adverse effects | Absorbable Implants - standards | Metals - standards | Humans | Risk Factors | Prosthesis Design - standards | Metals - adverse effects | Drug-Eluting Stents - adverse effects | Animals | Drug-Eluting Stents - standards | Prosthesis Design - methods | Tissue Scaffolds - standards | Stents - adverse effects | Stents - standards | Transluminal angioplasty | Stent (Surgery) | Alloys
Journal Article
JACC (Journal of the American College of Cardiology), ISSN 0735-1097, 2014, Volume 63, Issue 19, pp. 1972 - 1981
Objectives This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis...
Cardiovascular | Internal Medicine | transcatheter aortic valve replacement | outcomes | aortic stenosis | REQUIREMENTS | CARDIAC & CARDIOVASCULAR SYSTEMS | METAANALYSIS | PERMANENT PACEMAKER | IMPACT | IMPLANTATION | BALLOON | VALVULOPLASTY | CONDUCTION ABNORMALITIES | ELDERLY-PATIENTS | Severity of Illness Index | Heart Valve Prosthesis Implantation - instrumentation | Prospective Studies | Follow-Up Studies | Bioprosthesis - standards | Humans | Risk Factors | Prosthesis Design - standards | Heart Valve Prosthesis Implantation - methods | Male | Treatment Outcome | Aortic Valve Stenosis - diagnosis | Heart Valve Prosthesis - standards | Cardiac Catheterization - instrumentation | Cardiac Catheterization - methods | Aged, 80 and over | Female | Aged | Aortic Valve Stenosis - surgery | Sects | Care and treatment | Aortic valve stenosis | Surgery | Heart | Aspirin | Stroke | Medical imaging | Mortality | Medical prognosis | Cardiology | Patients | Catheters
Cardiovascular | Internal Medicine | transcatheter aortic valve replacement | outcomes | aortic stenosis | REQUIREMENTS | CARDIAC & CARDIOVASCULAR SYSTEMS | METAANALYSIS | PERMANENT PACEMAKER | IMPACT | IMPLANTATION | BALLOON | VALVULOPLASTY | CONDUCTION ABNORMALITIES | ELDERLY-PATIENTS | Severity of Illness Index | Heart Valve Prosthesis Implantation - instrumentation | Prospective Studies | Follow-Up Studies | Bioprosthesis - standards | Humans | Risk Factors | Prosthesis Design - standards | Heart Valve Prosthesis Implantation - methods | Male | Treatment Outcome | Aortic Valve Stenosis - diagnosis | Heart Valve Prosthesis - standards | Cardiac Catheterization - instrumentation | Cardiac Catheterization - methods | Aged, 80 and over | Female | Aged | Aortic Valve Stenosis - surgery | Sects | Care and treatment | Aortic valve stenosis | Surgery | Heart | Aspirin | Stroke | Medical imaging | Mortality | Medical prognosis | Cardiology | Patients | Catheters
Journal Article
Clinical and Translational Science, ISSN 1752-8054, 10/2015, Volume 8, Issue 5, pp. 594 - 600
Three‐dimensional (3D) printing, or additive manufacturing, technology has rapidly penetrated the medical device industry over the past several years, and...
FDA | translational research | imaging | computers | methodology | surgery | Computers | Translational research | Methodology | Imaging | Surgery | MEDICINE, RESEARCH & EXPERIMENTAL | TRACHEOBRONCHOMALACIA | VALIDATION | FINITE-ELEMENT | OPTIMIZATION | FABRICATION | Absorbable Implants - adverse effects | Health Care Sector - standards | Absorbable Implants - standards | Risk Assessment | Humans | Prosthesis Design - standards | Tomography, X-Ray Computed | Printing, Three-Dimensional - standards | Trachea - diagnostic imaging | Health Care Sector - legislation & jurisprudence | Tracheobronchomalacia - diagnostic imaging | Bronchography - methods | Printing, Three-Dimensional - legislation & jurisprudence | Patient Safety - legislation & jurisprudence | Medical Device Legislation - standards | Computer-Aided Design | Health Policy | Bronchi - pathology | Radiographic Image Interpretation, Computer-Assisted | Practice Guidelines as Topic | Tracheobronchomalacia - therapy | Implants, Artificial | Prosthesis | Medical equipment | Medical device industry | Manufacturing | Review | Original s
FDA | translational research | imaging | computers | methodology | surgery | Computers | Translational research | Methodology | Imaging | Surgery | MEDICINE, RESEARCH & EXPERIMENTAL | TRACHEOBRONCHOMALACIA | VALIDATION | FINITE-ELEMENT | OPTIMIZATION | FABRICATION | Absorbable Implants - adverse effects | Health Care Sector - standards | Absorbable Implants - standards | Risk Assessment | Humans | Prosthesis Design - standards | Tomography, X-Ray Computed | Printing, Three-Dimensional - standards | Trachea - diagnostic imaging | Health Care Sector - legislation & jurisprudence | Tracheobronchomalacia - diagnostic imaging | Bronchography - methods | Printing, Three-Dimensional - legislation & jurisprudence | Patient Safety - legislation & jurisprudence | Medical Device Legislation - standards | Computer-Aided Design | Health Policy | Bronchi - pathology | Radiographic Image Interpretation, Computer-Assisted | Practice Guidelines as Topic | Tracheobronchomalacia - therapy | Implants, Artificial | Prosthesis | Medical equipment | Medical device industry | Manufacturing | Review | Original s
Journal Article
International journal of computerized dentistry, ISSN 1463-4201, 2015, Volume 18, Issue 4, pp. 343 - 367
As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice....
FIT | geometric approximations | geometric defects | DENTISTRY, ORAL SURGERY & MEDICINE | digital dentistry | accuracy | dental CAD/CAM | FUTURE | TOOTH | TECHNOLOGY | DENTISTRY | User-Computer Interface | Reproducibility of Results | Technology, Dental - standards | Dental Prosthesis - statistics & numerical data | Humans | Workflow | Engineering - standards | Computer-Aided Design - instrumentation | Equipment Design | Dental Prosthesis Design - standards | Algorithms | Computer-Aided Design - standards | Dental Prosthesis - standards | Computer-Aided Design - statistics & numerical data | Computer Simulation | Surface Properties | Dental Prosthesis Design - statistics & numerical data | Mechanics | Engineering Sciences | Mechanical engineering
FIT | geometric approximations | geometric defects | DENTISTRY, ORAL SURGERY & MEDICINE | digital dentistry | accuracy | dental CAD/CAM | FUTURE | TOOTH | TECHNOLOGY | DENTISTRY | User-Computer Interface | Reproducibility of Results | Technology, Dental - standards | Dental Prosthesis - statistics & numerical data | Humans | Workflow | Engineering - standards | Computer-Aided Design - instrumentation | Equipment Design | Dental Prosthesis Design - standards | Algorithms | Computer-Aided Design - standards | Dental Prosthesis - standards | Computer-Aided Design - statistics & numerical data | Computer Simulation | Surface Properties | Dental Prosthesis Design - statistics & numerical data | Mechanics | Engineering Sciences | Mechanical engineering
Journal Article
Journal of the American College of Cardiology, ISSN 0735-1097, 08/2015, Volume 66, Issue 7, pp. 791 - 800
Background The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable...
self-expandable | aortic stenosis | balloon-expandable | TAVR | SURGERY | CARDIAC & CARDIOVASCULAR SYSTEMS | STENOSIS | EDWARDS SAPIEN | RISK | IMPACT | REGURGITATION | PREDICTORS | IMPLANTATION TAVI | PROSTHESIS | REGISTRY | Prospective Studies | Follow-Up Studies | Transcatheter Aortic Valve Replacement - standards | Humans | Middle Aged | Prosthesis Design - standards | Male | Treatment Outcome | Aortic Valve Stenosis - diagnosis | Balloon Valvuloplasty - trends | Heart Valve Prosthesis - standards | Balloon Valvuloplasty - standards | Time Factors | Transcatheter Aortic Valve Replacement - trends | Aged, 80 and over | Female | Aged | Aortic Valve Stenosis - surgery | Prosthesis Design - trends | Heart Valve Prosthesis - trends | Clinical trials | Aortic valve stenosis
self-expandable | aortic stenosis | balloon-expandable | TAVR | SURGERY | CARDIAC & CARDIOVASCULAR SYSTEMS | STENOSIS | EDWARDS SAPIEN | RISK | IMPACT | REGURGITATION | PREDICTORS | IMPLANTATION TAVI | PROSTHESIS | REGISTRY | Prospective Studies | Follow-Up Studies | Transcatheter Aortic Valve Replacement - standards | Humans | Middle Aged | Prosthesis Design - standards | Male | Treatment Outcome | Aortic Valve Stenosis - diagnosis | Balloon Valvuloplasty - trends | Heart Valve Prosthesis - standards | Balloon Valvuloplasty - standards | Time Factors | Transcatheter Aortic Valve Replacement - trends | Aged, 80 and over | Female | Aged | Aortic Valve Stenosis - surgery | Prosthesis Design - trends | Heart Valve Prosthesis - trends | Clinical trials | Aortic valve stenosis
Journal Article
Journal of Prosthetic Dentistry, ISSN 0022-3913, 2016, Volume 116, Issue 3, pp. 328 - 335.e2
Abstract Statement of problem In existing published reports, some studies indicate the superiority of digital impression systems in terms of the marginal...
Dentistry | DESIGN | CAD/CAM CROWNS | ZIRCONIA | CLINICAL-EVALUATION | DENTISTRY, ORAL SURGERY & MEDICINE | PROSTHESES | PASSIVE FIT | FIXED PARTIAL DENTURES | CROWNS IN-VITRO | INTERNAL FIT | ACCURACY | Dental Prosthesis Design - standards | Dental Marginal Adaptation - standards | Humans | Ceramics - therapeutic use | Dental Restoration, Permanent - standards | Computer-Aided Design | Dental Impression Technique | Dental Prosthesis Design - methods | Dental Restoration, Permanent - methods | Implants, Artificial | Prosthesis | Analysis
Dentistry | DESIGN | CAD/CAM CROWNS | ZIRCONIA | CLINICAL-EVALUATION | DENTISTRY, ORAL SURGERY & MEDICINE | PROSTHESES | PASSIVE FIT | FIXED PARTIAL DENTURES | CROWNS IN-VITRO | INTERNAL FIT | ACCURACY | Dental Prosthesis Design - standards | Dental Marginal Adaptation - standards | Humans | Ceramics - therapeutic use | Dental Restoration, Permanent - standards | Computer-Aided Design | Dental Impression Technique | Dental Prosthesis Design - methods | Dental Restoration, Permanent - methods | Implants, Artificial | Prosthesis | Analysis
Journal Article
Journal of the American College of Cardiology, ISSN 0735-1097, 04/2013, Volume 61, Issue 15, pp. 1585 - 1595
Objectives: This study was designed to establish the incidence, impact, and predictors of post-transcatheter aortic valve replacement (TAVR) aortic...
CoreValve | post-TAVR AR | predictors of AR post-TAVR | mild AR | TAVI | MULTICENTER | CARDIAC & CARDIOVASCULAR SYSTEMS | STENOSIS | HIGH-RISK PATIENTS | IMPLANTATION | RECOMMENDATIONS | EXPERIENCE | ECHOCARDIOGRAPHY | Equipment Failure Analysis - statistics & numerical data | Severity of Illness Index | Heart Valve Prosthesis Implantation - instrumentation | Postoperative Complications - physiopathology | Risk Assessment | Humans | Risk Factors | Heart Valve Prosthesis - adverse effects | Kaplan-Meier Estimate | Prosthesis Design - standards | Aortic Valve Insufficiency - physiopathology | Heart Valve Prosthesis Implantation - methods | Treatment Outcome | Data Collection | Postoperative Complications - epidemiology | Aortic Valve - surgery | Heart Valve Prosthesis - standards | Aortic Valve Insufficiency - etiology | Incidence | Heart Valve Prosthesis Implantation - adverse effects | Cardiac Catheterization - methods | Aortic Valve Stenosis - surgery | Prosthesis Failure - etiology | Aortic Valve Insufficiency - epidemiology
CoreValve | post-TAVR AR | predictors of AR post-TAVR | mild AR | TAVI | MULTICENTER | CARDIAC & CARDIOVASCULAR SYSTEMS | STENOSIS | HIGH-RISK PATIENTS | IMPLANTATION | RECOMMENDATIONS | EXPERIENCE | ECHOCARDIOGRAPHY | Equipment Failure Analysis - statistics & numerical data | Severity of Illness Index | Heart Valve Prosthesis Implantation - instrumentation | Postoperative Complications - physiopathology | Risk Assessment | Humans | Risk Factors | Heart Valve Prosthesis - adverse effects | Kaplan-Meier Estimate | Prosthesis Design - standards | Aortic Valve Insufficiency - physiopathology | Heart Valve Prosthesis Implantation - methods | Treatment Outcome | Data Collection | Postoperative Complications - epidemiology | Aortic Valve - surgery | Heart Valve Prosthesis - standards | Aortic Valve Insufficiency - etiology | Incidence | Heart Valve Prosthesis Implantation - adverse effects | Cardiac Catheterization - methods | Aortic Valve Stenosis - surgery | Prosthesis Failure - etiology | Aortic Valve Insufficiency - epidemiology
Journal Article
Brain, ISSN 0006-8950, 2017, Volume 140, Issue 6, pp. 1680 - 1691
There exist significant clinical and basic research needs for accurate, automated seizure detection algorithms. These algorithms have translational potential...
Crowdsourcing | Intracranial EEG | Seizure detection | Epilepsy | Experimental models | epilepsy | LONG-TERM | crowdsourcing | PERFORMANCE | ARTIFICIAL NEURAL-NETWORK | IDENTIFICATION | NEUROSCIENCES | CLINICAL NEUROLOGY | intracranial EEG | PREDICTION | CANINE EPILEPSY | seizure detection | experimental models | RESPONSIVE CORTICAL STIMULATION | ONSET DETECTION | INTRACTABLE EPILEPSY | Reproducibility of Results | Crowdsourcing - standards | Humans | Equipment Design - standards | Prostheses and Implants | Seizures - diagnosis | Electrocorticography - standards | Algorithms | Animals | Equipment Design - methods | Adult | Crowdsourcing - methods | Electrocorticography - methods | Disease Models, Animal | Original
Crowdsourcing | Intracranial EEG | Seizure detection | Epilepsy | Experimental models | epilepsy | LONG-TERM | crowdsourcing | PERFORMANCE | ARTIFICIAL NEURAL-NETWORK | IDENTIFICATION | NEUROSCIENCES | CLINICAL NEUROLOGY | intracranial EEG | PREDICTION | CANINE EPILEPSY | seizure detection | experimental models | RESPONSIVE CORTICAL STIMULATION | ONSET DETECTION | INTRACTABLE EPILEPSY | Reproducibility of Results | Crowdsourcing - standards | Humans | Equipment Design - standards | Prostheses and Implants | Seizures - diagnosis | Electrocorticography - standards | Algorithms | Animals | Equipment Design - methods | Adult | Crowdsourcing - methods | Electrocorticography - methods | Disease Models, Animal | Original
Journal Article
Journal of Prosthetic Dentistry, ISSN 0022-3913, 2016, Volume 116, Issue 3, pp. 368 - 374
Abstract Statement of problem Marginal and axial discrepancies of metal ceramic restorations are key to their long-term success. Little information is...
Dentistry | CROWNS | DENTAL ALLOYS | DENTISTRY, ORAL SURGERY & MEDICINE | FUTURE PERSPECTIVES | ADAPTATION | FIXED PARTIAL DENTURES | PORCELAIN | CHROMIUM | BOND STRENGTH | INTERNAL FIT | COPINGS | Tooth, Artificial | Humans | Dental Restoration, Permanent - standards | Dental Prosthesis Design - instrumentation | Dental Restoration, Permanent - instrumentation | Dental Prosthesis Design - standards | Metal Ceramic Alloys - therapeutic use | Dental Marginal Adaptation - standards | Computer-Aided Design | In Vitro Techniques | Dental Occlusion | Chromium Alloys - therapeutic use | Dental Prosthesis Design - methods | Dental Restoration, Permanent - methods | Analysis | Sintering | College teachers
Dentistry | CROWNS | DENTAL ALLOYS | DENTISTRY, ORAL SURGERY & MEDICINE | FUTURE PERSPECTIVES | ADAPTATION | FIXED PARTIAL DENTURES | PORCELAIN | CHROMIUM | BOND STRENGTH | INTERNAL FIT | COPINGS | Tooth, Artificial | Humans | Dental Restoration, Permanent - standards | Dental Prosthesis Design - instrumentation | Dental Restoration, Permanent - instrumentation | Dental Prosthesis Design - standards | Metal Ceramic Alloys - therapeutic use | Dental Marginal Adaptation - standards | Computer-Aided Design | In Vitro Techniques | Dental Occlusion | Chromium Alloys - therapeutic use | Dental Prosthesis Design - methods | Dental Restoration, Permanent - methods | Analysis | Sintering | College teachers
Journal Article
Applied Optics, ISSN 1559-128X, 05/2017, Volume 56, Issue 15, pp. 4338 - 4346
We present an opto-mechanical artificial eye that can be used for examining multi-wavelength ophthalmic instruments. Standard off-the-shelf lenses and a...
SYSTEM | IN-VITRO | MULTIFOCAL INTRAOCULAR LENSES | SPHERICAL-ABERRATION | CHROMATIC ABERRATION | IMAGE QUALITY | PERFORMANCE | ADAPTIVE OPTICS | OPTICS | MODEL EYE | SOFT CONTACT-LENSES | Aberrometry - instrumentation | Eye, Artificial - standards | Ophthalmology - instrumentation | Prosthesis Design - standards | Aberration | Research | Refractive index | Analysis
SYSTEM | IN-VITRO | MULTIFOCAL INTRAOCULAR LENSES | SPHERICAL-ABERRATION | CHROMATIC ABERRATION | IMAGE QUALITY | PERFORMANCE | ADAPTIVE OPTICS | OPTICS | MODEL EYE | SOFT CONTACT-LENSES | Aberrometry - instrumentation | Eye, Artificial - standards | Ophthalmology - instrumentation | Prosthesis Design - standards | Aberration | Research | Refractive index | Analysis
Journal Article
International Journal of Oral and Maxillofacial Implants, ISSN 0882-2786, 2016, Volume 31, Issue 3, pp. 601 - 609
Purpose: Zirconia is being widely used, at times apparently by simply copying a metal design into ceramic. Structurally, ceramics are sensitive to both design...
Zirconia | Titanium | Fatigue | CAD/CAM abutments | Implant abutments | implant abutments | fatigue | MODES | titanium | DENTISTRY, ORAL SURGERY & MEDICINE | zirconia | RELIABILITY | Dental Porcelain - chemistry | Humans | Titanium - chemistry | Stress, Mechanical | Dental Implant-Abutment Design - standards | Dental Implant-Abutment Design - methods | Dental Abutments - standards | Materials Testing - methods | Ceramics - chemistry | Prosthesis Failure | Zirconium - chemistry | Dental Stress Analysis - methods | Computer-Aided Design
Zirconia | Titanium | Fatigue | CAD/CAM abutments | Implant abutments | implant abutments | fatigue | MODES | titanium | DENTISTRY, ORAL SURGERY & MEDICINE | zirconia | RELIABILITY | Dental Porcelain - chemistry | Humans | Titanium - chemistry | Stress, Mechanical | Dental Implant-Abutment Design - standards | Dental Implant-Abutment Design - methods | Dental Abutments - standards | Materials Testing - methods | Ceramics - chemistry | Prosthesis Failure | Zirconium - chemistry | Dental Stress Analysis - methods | Computer-Aided Design
Journal Article