X
Search Filters
Format Format
Format Format
X
Sort by Item Count (A-Z)
Filter by Count
Journal Article (2105) 2105
Book Review (119) 119
Publication (111) 111
Conference Proceeding (50) 50
Book Chapter (13) 13
Dissertation (13) 13
Trade Publication Article (7) 7
Web Resource (4) 4
Book / eBook (1) 1
more...
Subjects Subjects
Subjects Subjects
X
Sort by Item Count (A-Z)
Filter by Count
index medicus (1585) 1585
humans (1395) 1395
radiology, nuclear medicine & medical imaging (1206) 1206
tomotherapy (1118) 1118
helical tomotherapy (1103) 1103
oncology (1080) 1080
radiotherapy (1045) 1045
radiotherapy dosage (810) 810
imrt (656) 656
male (646) 646
radiotherapy, intensity-modulated - methods (587) 587
radiation-therapy (571) 571
radiotherapy planning, computer-assisted - methods (563) 563
female (544) 544
cancer (496) 496
radiation therapy (455) 455
middle aged (431) 431
aged (388) 388
dosimetry (388) 388
intensity-modulated radiotherapy (386) 386
hematology, oncology and palliative medicine (363) 363
patients (293) 293
adult (289) 289
radiology (289) 289
radiotherapy planning, computer-assisted (279) 279
radiation (267) 267
radiology and nuclear medicine (256) 256
irradiation (253) 253
algorithms (252) 252
treatment outcome (247) 247
delivery (239) 239
head (239) 239
prostatic neoplasms - radiotherapy (227) 227
phantoms, imaging (225) 225
planning (222) 222
radiotherapy, conformal - methods (222) 222
therapy (222) 222
computerized tomography (221) 221
conformal radiotherapy (221) 221
care and treatment (218) 218
radiation doses (215) 215
aged, 80 and over (192) 192
ct-guided radiotherapy (190) 190
optimization (186) 186
head and neck neoplasms - radiotherapy (184) 184
radiometry - methods (179) 179
toxicity (174) 174
retrospective studies (164) 164
reproducibility of results (163) 163
intensity modulated radiation therapy (159) 159
radiotherapy, intensity-modulated (158) 158
tumors (157) 157
neoplasms (155) 155
radiotherapy, intensity-modulated - adverse effects (155) 155
chemotherapy (151) 151
research (151) 151
prostate cancer (146) 146
dose fractionation (145) 145
vmat (143) 143
modulated radiation-therapy (134) 134
neoplasms - radiotherapy (133) 133
radiometry (133) 133
sensitivity and specificity (129) 129
prostate (127) 127
verification (123) 123
breast neoplasms - radiotherapy (121) 121
carcinoma (120) 120
engineering, biomedical (119) 119
feasibility studies (118) 118
radiation dosage (117) 117
tomography, x-ray computed (116) 116
linear accelerators (113) 113
medical imaging (113) 113
neoplasm staging (110) 110
tomography, x-ray computed - methods (110) 110
computed tomography (109) 109
lung neoplasms - radiotherapy (109) 109
surgery (109) 109
phantoms (107) 107
quality assurance (107) 107
system (107) 107
breast cancer (106) 106
lungs (106) 106
accuracy (105) 105
dose-response relationship, radiation (104) 104
tomography, spiral computed - methods (104) 104
analysis (103) 103
neck-cancer (102) 102
radiation protection and dosimetry (102) 102
radiosurgery (101) 101
medicine & public health (99) 99
radiation oncology physics (99) 99
randomized-trial (98) 98
tomography (98) 98
neck (97) 97
computer simulation (96) 96
multileaf collimators (95) 95
organs at risk (95) 95
time factors (95) 95
radiation injuries - prevention & control (94) 94
more...
Language Language
Language Language
X
Sort by Item Count (A-Z)
Filter by Count
English (2023) 2023
French (84) 84
German (23) 23
Korean (21) 21
Chinese (8) 8
Italian (6) 6
Polish (3) 3
Japanese (2) 2
Spanish (2) 2
Turkish (1) 1
more...
Publication Date Publication Date
Click on a bar to filter by decade
Slide to change publication date range


Cancer/Radiotherapie, ISSN 1278-3218, 02/2018, Volume 22, Issue 1, pp. 17 - 24
Purpose: Helical TomoTherapy allows precise and homogeneous tumour coverage and excellent sparing of organs at risk. We present here our treatment technique,... 
Total body irradiation | Helical TomoTherapy | TBI | TomoTherapy
Journal Article
Radiotherapy and Oncology, ISSN 0167-8140, 06/2016, Volume 119, Issue 3, pp. 519 - 524
Purpose To optimize the local control of stereotactic body radiotherapy (SBRT) using the Vero-SBRT system and respiratory motion management in patients with... 
Motion management | Vero | Oligometastases | SBRT | Tomotherapy
Journal Article
Cancer/Radiotherapie, ISSN 1278-3218, 10/2016, Volume 20, Issue 6-7, pp. 608 - 610
Tomotherapy is a technique of IMRT and IGRT using a linear accelerator and a helical CT-scanner. To reach this targeting of precision, the repositioning of the... 
Repositioing | Tomotherapy | Imagery | Delegation
Journal Article
08/2008
The purpose of this study was to measure the multileaf collimator (MLC) transmission from the first Hi-Art II tomotherapy machine installed at the Advanced... 
tomotherapy | Film | multileaf collimator transmission | ion chamber
Web Resource
Oncotarget, ISSN 1949-2553, 2017, Volume 8, Issue 51, pp. 89086 - 89094
Objective: The purpose of this study was to evaluate CTV-PTV margins of tumors for tomotherapy. Methods: Setup errors were analyzed for 151 patients receiving... 
Heterogeneity | Tomotherapy | CTV-PTV margins | MVCT | Setup errors | tomotherapy | setup errors | HELICAL TOMOTHERAPY | heterogeneity | SETUP | CELL BIOLOGY
Journal Article
Journal of Magnetics, ISSN 1226-1750, 2016, Volume 21, Issue 3, pp. 425 - 430
Journal Article
International Journal of Radiation Oncology Biology Physics, ISSN 0360-3016, 11/2011, Volume 81, Issue 3, pp. 856 - 862
Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body... 
Central lesions | Helical tomotherapy | Lung cancer | SBRT
Journal Article
Physics in Medicine and Biology, ISSN 0031-9155, 01/2019, Volume 64, Issue 2, pp. 025020 - 025020
Aim of the present study was to evaluate the accuracy which can be obtained with helical TomoTherapy (R) (HT, Accuray) systems in the case of multiple... 
in phantom setup accuracy | multiple brain metastasis | TomoTherapy | SINGLE | BOOST | ENGINEERING, BIOMEDICAL | METASTASES | STEREOTACTIC RADIOSURGERY | MEGAVOLTAGE | GAMMA-KNIFE | REGISTRATION | HELICAL TOMOTHERAPY | QUALITY-ASSURANCE | CYBERKNIFE | RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal Article
Medical Dosimetry, ISSN 0958-3947, 2019
To compare the dosimetric results of helical tomotherapy (HT) and volumetric arc therapy (VMAT) in the treatment of anal cancer. Plans were created for 20 (n =... 
VMAT | Helical tomotherapy | Anal cancer | Dosimetric comparison
Journal Article
Medical Physics, ISSN 0094-2405, 01/2018, Volume 45, Issue 1, pp. 18 - 28
Purpose: Anatomical motion, both cyclical and aperiodic, can impact the dose delivered during external beam radiation. In this work, we evaluate the use of a... 
dose calculation | tomotherapy | motion compensation | intrafractional motion | PROSTATE | INTRA-FRACTION MOTION | VALIDATION | DELIVERY | IMPACT | TUMOR MOTION | RADIOTHERAPY | HELICAL TOMOTHERAPY | RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING | Index Medicus
Journal Article
International journal of radiation oncology, biology, physics, ISSN 0360-3016, 11/2016, Volume 96, Issue 3, pp. 688 - 695
Journal Article
Journal of Radiotherapy in Practice, ISSN 1460-3969, 03/2017, Volume 16, Issue 1, pp. 109 - 112
  Background Desmoid tumour is a rare neoplasm occurring intra- and extra-abdominally. Method In this study, a lower extremity desmoid tumour located close to... 
ovary | tomotherapy | IMRT | desmoid tumour
Journal Article
Cancer/Radiotherapie, ISSN 1278-3218, 12/2017, Volume 21, Issue 8, pp. 749 - 758
Purpose This work proposes a comparative evaluation of two of our patient-specific quality assurance processes involving ArcCHECK (Sun Nuclear) and Gafchromic... 
ArcCHECK | Gafchromic EBT3 films | DQA | Tomotherapy
Journal Article
12/2010
Background: Linear Accelerator-based Intensity Modulated Radiation Therapy (IMRT), either as step-and shoot (SS) or in dynamic mode, is now considered routine... 
tomotherapy | Dosimetric comparison | normal tissue complication probabilities | intensity modulated radiation therapy
Web Resource
Cancer/Radiotherapie, ISSN 1278-3218, 12/2017, Volume 21, Issue 8, pp. 741 - 748
Purpose To evaluate the dosimetric contribution of helical tomotherapy for breast cancers compared with conformal radiotherapy in mono-isocentric technique.... 
Mono-isocentric technic | Breast cancer | Tomotherapy
Journal Article
05/2010
Purpose : To characterize metal oxide semiconductor field-effect transistors (MOSFETs) for a 6-MV photon beam with a first helical tomotherapy Hi-Art II unit... 
thermoluminescence dosimeter | Ion chamber | tomotherapy | metal oxide semiconductor field-effect transistor
Web Resource
No results were found for your search.

Cannot display more than 1000 results, please narrow the terms of your search.