Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 2010, Volume 621, Issue 1, pp. 424 - 430
Because of the low mobility of holes, CdZnTe (CZT) detectors operate as electron-transport-only type devices whose particular geometrical parameters and...
Gamma-ray detectors | Virtual Frisch-grid detectors | CdZnTe | INSTRUMENTS & INSTRUMENTATION | SPECTROSCOPY | CDZNTE DETECTORS | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | PHYSICS, PARTICLES & FIELDS | Emergency medical services | Detectors | Electrodes | Accelerators | Anode effect | Crystals | Shielding | Devices | Cathodes | gamma-ray detectors | Frisch-grid | CZT | 98
Gamma-ray detectors | Virtual Frisch-grid detectors | CdZnTe | INSTRUMENTS & INSTRUMENTATION | SPECTROSCOPY | CDZNTE DETECTORS | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | PHYSICS, PARTICLES & FIELDS | Emergency medical services | Detectors | Electrodes | Accelerators | Anode effect | Crystals | Shielding | Devices | Cathodes | gamma-ray detectors | Frisch-grid | CZT | 98
Journal Article
Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 02/2013, Volume 701, pp. 208 - 213
Detector grade CZT single crystals have been grown from zone refined Cd, Zn, and Te (∼7 N) precursor materials using a tellurium solvent method. Infrared...
Virtual Frisch grid | Gamma/x-ray detector | Biparametric correction | CdZnTe | INSTRUMENTS & INSTRUMENTATION | CDZNTE RADIATION DETECTORS | SPECTROSCOPY | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | GROWTH | CRYSTALS | PHYSICS, PARTICLES & FIELDS | Gamma rays | Cadmium | Spectroscopy | Energy resolution | Detectors | Digitization | Digital | Tellurium
Virtual Frisch grid | Gamma/x-ray detector | Biparametric correction | CdZnTe | INSTRUMENTS & INSTRUMENTATION | CDZNTE RADIATION DETECTORS | SPECTROSCOPY | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | GROWTH | CRYSTALS | PHYSICS, PARTICLES & FIELDS | Gamma rays | Cadmium | Spectroscopy | Energy resolution | Detectors | Digitization | Digital | Tellurium
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 10/2017, Volume 64, Issue 10, pp. 2698 - 2705
Journal Article
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, 07/2018
Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma...
CdZnTe detectors | INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY | 3D charge-loss correction | CdZnTe | Position-sensitive virtual Frisch-grid detectors
CdZnTe detectors | INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY | 3D charge-loss correction | CdZnTe | Position-sensitive virtual Frisch-grid detectors
Journal Article
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, 2018
Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma...
CdZnTe detectors | 3D charge-loss correction | Position-sensitive virtual Frisch-grid detectors | CdZnTe
CdZnTe detectors | 3D charge-loss correction | Position-sensitive virtual Frisch-grid detectors | CdZnTe
Journal Article
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, ISSN 0018-9499, 10/2017, Volume 64, Issue 10, pp. 2698 - 2705
Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal...
NUCLEAR SCIENCE & TECHNOLOGY | charge-loss correction | READOUT | 3-D position-sensitive virtual Frisch-grid (VFG) detectors | high-granularity detectors | CdZnTe (CZT) | crystal defects | ENGINEERING, ELECTRICAL & ELECTRONIC
NUCLEAR SCIENCE & TECHNOLOGY | charge-loss correction | READOUT | 3-D position-sensitive virtual Frisch-grid (VFG) detectors | high-granularity detectors | CdZnTe (CZT) | crystal defects | ENGINEERING, ELECTRICAL & ELECTRONIC
Journal Article
Journal of Optoelectronics and Advanced Materials, ISSN 1454-4164, 05/2012, Volume 14, Issue 5-6, pp. 497 - 503
Recent years, CdZnTe detectors have captured great interests in the field of gamma ray detection for their special characteristics. The configuration of...
Capacitive virtual Frisch grid | CdZnTe detector | Spectra | COLLECTION | RADIATION DETECTORS | PHYSICS, APPLIED | SPECTROMETERS | PASSIVATION | MATERIALS SCIENCE, MULTIDISCIPLINARY | CDZNTE | OPTICS
Capacitive virtual Frisch grid | CdZnTe detector | Spectra | COLLECTION | RADIATION DETECTORS | PHYSICS, APPLIED | SPECTROMETERS | PASSIVATION | MATERIALS SCIENCE, MULTIDISCIPLINARY | CDZNTE | OPTICS
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 10/2017, Volume 64, Issue 10, pp. 2698 - 2705
Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal...
cdZnTe (CZT) | Energy resolution | charge-loss correction | Detectors | Crystals | 3-D position-sensitive virtual Frisch-grid (VFG) detectors | high-granularity detectors | Timing | Anodes | Cathodes | Testing | crystal defects | Crystal defects | Medical imaging | Energy use | Gamma rays | Quality | Prototypes | Performance enhancement | Cameras | Sensors | Cadmium zinc tellurides | Astronomy | OTHER INSTRUMENTATION
cdZnTe (CZT) | Energy resolution | charge-loss correction | Detectors | Crystals | 3-D position-sensitive virtual Frisch-grid (VFG) detectors | high-granularity detectors | Timing | Anodes | Cathodes | Testing | crystal defects | Crystal defects | Medical imaging | Energy use | Gamma rays | Quality | Prototypes | Performance enhancement | Cameras | Sensors | Cadmium zinc tellurides | Astronomy | OTHER INSTRUMENTATION
Journal Article
9.
Full Text
A linear array of position-sensitive virtual Frisch-grid CdZnTe for low-energy gamma rays
Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 09/2018, Volume 903, Issue C, pp. 204 - 214
Large-area arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution and high efficiency have been proposed for...
High-granularity detectors | 3D position-sensitive virtual Frisch-grid detectors | Crystal defects | CdZnTe | Charge-loss correction | DETECTORS | INSTRUMENTS & INSTRUMENTATION | NUCLEAR SCIENCE & TECHNOLOGY | SIGNALS | READOUT | PHYSICS, NUCLEAR | PHYSICS, PARTICLES & FIELDS | INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
High-granularity detectors | 3D position-sensitive virtual Frisch-grid detectors | Crystal defects | CdZnTe | Charge-loss correction | DETECTORS | INSTRUMENTS & INSTRUMENTATION | NUCLEAR SCIENCE & TECHNOLOGY | SIGNALS | READOUT | PHYSICS, NUCLEAR | PHYSICS, PARTICLES & FIELDS | INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 08/2012, Volume 59, Issue 4, pp. 1544 - 1551
New results from testing an array of 6 \,\times\, 6 \,\times\, 15 mm ^{3} virtual Frisch-grid CdZnTe (CZT) detectors with common-cathode readout for charge...
Application specific integrated circuits | virtual Frisch-grid detectors | CdZnTe | Detectors | Crystals | Arrays | Anodes | Cathodes | crystal defects | ELECTRODE GEOMETRY | POSITION-SENSITIVE DETECTORS | CDZNTE DETECTORS | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | IMPROVEMENT | ENGINEERING, ELECTRICAL & ELECTRONIC | Radiation warning systems | Electric charge and distribution | Measurement | Usage | Analysis | Innovations | Signal processing | Simulation methods | Pixels | Rejection | Electrodes | Charge | CZT | Channels
Application specific integrated circuits | virtual Frisch-grid detectors | CdZnTe | Detectors | Crystals | Arrays | Anodes | Cathodes | crystal defects | ELECTRODE GEOMETRY | POSITION-SENSITIVE DETECTORS | CDZNTE DETECTORS | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | IMPROVEMENT | ENGINEERING, ELECTRICAL & ELECTRONIC | Radiation warning systems | Electric charge and distribution | Measurement | Usage | Analysis | Innovations | Signal processing | Simulation methods | Pixels | Rejection | Electrodes | Charge | CZT | Channels
Journal Article
Applied Radiation and Isotopes, ISSN 0969-8043, 11/2019, Volume 153, p. 108818
The performance of a virtual (6 6 15 mm ) Frisch-grid cadmium zinc telluride detector for the detection of contraband with 14 MeV neutron-activation prompt...
Detection of contraband materials | Virtual frisch-grid cadmium zinc telluride (CZT) | Minimum detectable concentration (MDC) | Sensitive nonlinear iterative peak clipping algorithm (SNIP) | Prompt γ-ray neutron activation analysis (PGNAA)
Detection of contraband materials | Virtual frisch-grid cadmium zinc telluride (CZT) | Minimum detectable concentration (MDC) | Sensitive nonlinear iterative peak clipping algorithm (SNIP) | Prompt γ-ray neutron activation analysis (PGNAA)
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 08/2013, Volume 60, Issue 4, pp. 2875 - 2882
We discussed the design implementation and results from testing 2 × 2-, 3 × 3-, and 2 × 4-arrays of 6×6 ×15 mm 3 CdZnTe virtual Frisch-grid detectors. In these...
Application specific integrated circuits | Temperature measurement | CdZnTe | charge-loss correction | Detectors | Crystals | Anodes | virtual Frisch grid detectors | Cathodes | Testing | crystal defects | DEFECTS | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | READOUT | CHARGE-COLLECTION EVENTS | ENGINEERING, ELECTRICAL & ELECTRONIC | Integrated circuits | Temperature measurements | Research | Analysis | Data entry | Semiconductor chips
Application specific integrated circuits | Temperature measurement | CdZnTe | charge-loss correction | Detectors | Crystals | Anodes | virtual Frisch grid detectors | Cathodes | Testing | crystal defects | DEFECTS | NUCLEAR SCIENCE & TECHNOLOGY | PERFORMANCE | READOUT | CHARGE-COLLECTION EVENTS | ENGINEERING, ELECTRICAL & ELECTRONIC | Integrated circuits | Temperature measurements | Research | Analysis | Data entry | Semiconductor chips
Journal Article
Current Applied Physics, ISSN 1567-1739, 09/2015, Volume 15, pp. S51 - S56
Room-temperature semiconductor radiation detectors (RTSDs) such as cadmium zinc telluride (CZT) have been under development for several decades to provide a...
Single polarity sensing | Shielding electrode | Detection efficiency | CZT | Virtual Frisch-grid | PHYSICS, APPLIED | SEMICONDUCTOR | MATERIALS SCIENCE, MULTIDISCIPLINARY | COPLANAR ELECTRODES | Gamma rays | Detectors
Single polarity sensing | Shielding electrode | Detection efficiency | CZT | Virtual Frisch-grid | PHYSICS, APPLIED | SEMICONDUCTOR | MATERIALS SCIENCE, MULTIDISCIPLINARY | COPLANAR ELECTRODES | Gamma rays | Detectors
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 12/2015, Volume 62, Issue 6, pp. 3193 - 3198
The longer electron lifetime of today's CdZnTe (CZT) crystals allows for free carriers to travel longer distances in the crystals, which means that, in...
Image quality | virtual Frisch-grid detectors | CdZnTe | charge-loss correction | Crystals | Detectors | Nonhomogeneous media | Gamma-ray detectors | crystal defects | POSITION-SENSITIVE DETECTORS | NUCLEAR SCIENCE & TECHNOLOGY | CHAMBER | READOUT | CHARGE-COLLECTION EVENTS | ENGINEERING, ELECTRICAL & ELECTRONIC | Usage
Image quality | virtual Frisch-grid detectors | CdZnTe | charge-loss correction | Crystals | Detectors | Nonhomogeneous media | Gamma-ray detectors | crystal defects | POSITION-SENSITIVE DETECTORS | NUCLEAR SCIENCE & TECHNOLOGY | CHAMBER | READOUT | CHARGE-COLLECTION EVENTS | ENGINEERING, ELECTRICAL & ELECTRONIC | Usage
Journal Article
15.
Array of virtual Frisch-grid CZT detectors with common cathode readout and pulse-height correction
Proceedings of SPIE - The International Society for Optical Engineering, ISSN 0277-786X, 2010, Volume 7805
We present our new results from testing 15-mm-long virtual Frisch-grid CdZnTe detectors with a common-cathode readout for correcting pulse-height distortions....
CdZnTe detectors | virtual Frisch-grid detectors | crystal defects | Electrodes | Detectors | Shielding | Arrays | CZT | Devices | Cadmium zinc tellurides | Cathodes
CdZnTe detectors | virtual Frisch-grid detectors | crystal defects | Electrodes | Detectors | Shielding | Arrays | CZT | Devices | Cadmium zinc tellurides | Cathodes
Conference Proceeding
16.
Full Text
Rejecting incomplete charge-collection events in CdZnTe and other semiconductor detectors
Nuclear Inst. and Methods in Physics Research, A, ISSN 0168-9002, 2012, Volume 664, Issue 1, pp. 317 - 323
In an ideal single-carrier-type gamma ray detector, the amplitudes of the signals and the carrier drift times are correlated variables. However, if the charges...
CdZnTe detectors | Crystal defects | Event recognition | Virtual Frisch-grid detectors | INSTRUMENTS & INSTRUMENTATION | SPECTROSCOPY | NUCLEAR SCIENCE & TECHNOLOGY | PHYSICS, PARTICLES & FIELDS | Gamma rays | Algorithms | Emergency medical services | Detectors | Semiconductor industry
CdZnTe detectors | Crystal defects | Event recognition | Virtual Frisch-grid detectors | INSTRUMENTS & INSTRUMENTATION | SPECTROSCOPY | NUCLEAR SCIENCE & TECHNOLOGY | PHYSICS, PARTICLES & FIELDS | Gamma rays | Algorithms | Emergency medical services | Detectors | Semiconductor industry
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 2013, Volume 60, Issue 4, pp. 2853 - 2858
Journal Article
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, ISSN 0018-9499, 08/2013, Volume 60, Issue 4, pp. 2853 - 2858
Detector grade Cd0.9Zn0.1Te single crystals were grown using a tellurium solvent method. Single crystal blocks of volume similar to 1 cm(3) were prepared for...
Cd0.9Zn0.1Te (CZT) | virtual Frisch grid detector | CADMIUM ZINC TELLURIDE | small pixel effect | NUCLEAR RADIATION DETECTORS | Biparametric correlation | ENGINEERING, ELECTRICAL & ELECTRONIC | Te solvent method | digital data analyses | RAY DETECTORS | SPECTROMETERS | NUCLEAR SCIENCE & TECHNOLOGY | radiation detector | crystal growth
Cd0.9Zn0.1Te (CZT) | virtual Frisch grid detector | CADMIUM ZINC TELLURIDE | small pixel effect | NUCLEAR RADIATION DETECTORS | Biparametric correlation | ENGINEERING, ELECTRICAL & ELECTRONIC | Te solvent method | digital data analyses | RAY DETECTORS | SPECTROMETERS | NUCLEAR SCIENCE & TECHNOLOGY | radiation detector | crystal growth
Journal Article
IEEE Transactions on Nuclear Science, ISSN 0018-9499, 08/2013, Volume 60, Issue 4, pp. 2853 - 2858
Detector grade Cd 0.9 Zn 0.1 Te single crystals were grown using a tellurium solvent method. Single crystal blocks of volume ~1 cm 3 were prepared for detector...
virtual Frisch grid detector | Crystals | small pixel effect | Conductivity | Cd _{0.9} Zn _{0.1} Te (CZT) | Biparametric correlation | Zinc | Fabrication | Geometry | Te solvent method | digital data analyses | Energy resolution | radiation detector | Detectors | crystal growth
virtual Frisch grid detector | Crystals | small pixel effect | Conductivity | Cd _{0.9} Zn _{0.1} Te (CZT) | Biparametric correlation | Zinc | Fabrication | Geometry | Te solvent method | digital data analyses | Energy resolution | radiation detector | Detectors | crystal growth
Journal Article
Proceedings of SPIE - The International Society for Optical Engineering, ISSN 0277-786X, 2011, Volume 8142
Conference Proceeding
No results were found for your search.
Cannot display more than 1000 results, please narrow the terms of your search.